Our Product Range
Ora Cables PVT. LTD. is in the development, design, manufacture, marketing and distribution of Coaxial cables, CCTV, Access Control & Security, Data & Signalling, Single & Multicore Shielded / Non shielded, Armoured / Unarmoured, FR/FRLS, Instrumentation cables, RTD lead wire compensating cables & all kinds of specialized cables used in electronics industry.
ORACAB Submersible Cables
ORA 3core flat cable are specifically designed for indefinite immersion in water and protection against all kinds of atmospheric effects
& cables are made from best quality electrolytic copper which are bunched to ensure flexibility and uniform resistance
as per IS:694:1990
3 Core Flat Submersible Cable |
Conductor |
Insulation |
Sheath |
Conductor
Resistance
@ 20 C [Max]
OHMS/KM. |
Current
Carrying
Capacity
@40 C AMP |
Overall Dimensions |
Area
[Nom.]
Sq. mm. |
No. & Size
of wire in mm. |
Thickness
[Nom.]
mm. |
Core Dia.
[Nom.]
mm. |
Thickness
[Nom.]
mm. |
Size
[WxT]
mm. |
1.5 |
22/.03 |
... |
0.8 |
3.20 |
1.20 |
11.9x5.5 |
12.10 |
14 |
2.5 |
36/.03 |
... |
0.9 |
3.85 |
1.20 |
13.85x6.15 |
7.41 |
18 |
4.0 |
56/.03 |
... |
1.0 |
4.50 |
1.20 |
15.8x6.8 |
4.95 |
26 |
6.0 |
84/.03 |
... |
1.0 |
5.00 |
1.20 |
17.3x7.3 |
3.30 |
31 |
10.0 |
140/.03 |
... |
1.0 |
5.90 |
1.40 |
20.5x8.7 |
1.91 |
42 |
16.0 |
226/.03 |
126/.04 |
1.0 |
6.95 |
1.40 |
23.65x9.75 |
1.21 |
57 |
25.0 |
354/.03 |
196/.04 |
1.2 |
8.65 |
2.00 |
30x12.65 |
0.780 |
72 |
Note: As per the international practice which is also adopted by BIS, the size of the conductor is decided by its resistance only. The construction of the conductor mentioned in the table list are only for guidelines and are as per market convention. It may vary within the prescribed limit of IS:8130-1994 with related classes and tables. |
ORACAB House Service Wires
Single Core Plain Copper / Aluminum Conductor PVC insulated unsheathed/ Sheathed 650V/1100V house service wires as per IS:694:1990 with ISI Mark
Single Core Plain Copper/Aluminium Conductor PVC Insulated Unsheathed & PVC Sheathed 650/1100V., House Service Wires as per IS:694:1990 |
Conductor
Area
Sq. mm |
Conductor
Construction |
Max. DC Conductor
resistance at 20 C
in ohm/Km |
Unsheathed Cable |
Sheathed Cable |
Current Rating
Amp. |
Copper |
Aluminium |
Insulation
thickness
nominal
mm |
Overall
Diameter
Approx.
mm |
Insulation
thickness
nominal
mm |
Sheath
thickness
nominal
mm |
Overall
Diameter
Approx.
mm |
Copper |
Aluminium |
1.0
1.5
2.5 |
1/1.12
1/1.38
1/1.78 |
18.10
12.10
7.41 |
-
18.10
12.10 |
0.7
0.7
0.8 |
2.60
2.90
3.50 |
0.6
0.6
0.7 |
0.8
0.8
0.8 |
4.10
4.40
5.00 |
10
13
20 |
8
10
15 |
4
6
10
|
1/2.24
1/2.76
1/3.55AL.
7/1.35CU |
4.61
3.08
-
1.83 |
7.41
4.61
3.08
- |
0.8
0.8
1.0
|
4.00
4.50
5.70
6.20 |
0.8
0.8
1.0
|
0.9
0.9
0.9
|
5.85
6.50
7.55
|
26
35
44
|
20
27
34
|
16
25
35 |
7/1.70
7/2.14
7/2.50 |
1.15
0.727
0.524 |
1.91
1.20
0.868 |
1.0
1.2
1.2 |
7.20
8.90
10.00 |
1.0
1.2
1.2 |
1.0
1.1
1.1 |
9.30
11.20
12.30 |
55
75
90 |
43
58
70 |
50
70 |
7/3.0
19/1.78
19/2.14 |
0.387
0.268 |
0.641
0.443 |
1.4
1.4 |
11.90
11.90
13.60 |
1.4
1.4
|
1.2
1.2
|
14.40
14.40
|
120
120
150 |
92
92
116 |
95
120
150 |
19/2.50
37/2.03
37/2.24 |
0.193
0.153
0.124 |
0.320
0.253
0.206 |
1.6
1.6
1.8 |
15.80
17.50
19.40 |
|
|
|
175
200
230 |
135
155
175 |
185 |
37/2.50 |
0.0991 |
0.164 |
2.0 |
21.70 |
|
|
|
265 |
205 |
|
|
|
|
|
|
|
|
|
|
|
Note: As per the international practice which is also adopted by BIS, the size of the conductor is decided by its resistance only. The construction of the conductor mentioned in the table list are only for guidelines and are as per market convention. It may vary within the prescribed limit of IS:8130-1994 with related classes and tables. |
ORACAB Multicore Flexible Cables
ORA plane copper conductor PVC insulated and sheathed 650V/1100V, multicore flexible cable as per IS:694:1990 with ISI Mark
ORA Plain copper PVC insulated and Sheathed 650/1100V., Multicore flexible cable as per IS:694:1990 |
Normal
Area
in SQ.
MM |
No. of
Stands/
nominal
DIA. |
Maz. DC
Resistance
OHM/KM
AT20 C |
Normal
Insulation
Thichness
in MM |
Core
DIA
MM |
Normal
Sheath thickness in MM |
Overall Diameter
in MM [Approx.] |
Current
Rating |
2 CORE |
3 CORE |
4 CORE |
2 CORE |
3 CORE |
4 CORE |
0.50 |
16/0.20 |
39.00 |
0.60 |
2.20 |
0.90 |
0.90 |
0.90 |
6.20 |
6.60 |
7.20 |
4 |
0.75 |
24/0.20 |
26.00 |
0.60 |
2.50 |
0.90 |
0.90 |
0.90 |
6.80 |
7.20 |
7.90 |
7 |
1.00 |
32/0.20 |
19.50 |
0.60 |
2.60 |
0.90 |
0.90 |
0.90 |
7.00 |
7.50 |
8.10 |
11 |
1.50 |
48/0.20 |
13.30 |
0.60 |
2.90 |
0.90 |
0.90 |
1.00 |
7.60 |
8.10 |
9.00 |
14 |
2.50 |
80/0.20 |
7.98 |
0.70 |
3.50 |
1.00 |
1.00 |
1.00 |
9.00 |
9.60 |
10.50 |
19 |
4.00 |
56/0.30 |
4.95 |
0.80 |
4.30 |
1.00 |
1.00 |
1.00 |
10.60 |
11.30 |
12.40 |
26 |
Note: As per the international practice which is also adopted by BIS, the size of the conductor is decided by its resistance only. The construction of the conductor mentioned in the table list are only for guidelines and are as per market convention. It may vary within the prescribed limit of IS:8130-1994 with related classes and tables. |
ORACAB Copper Flexible Cables
ORA plain copper cundoctor PVC insulated unsheathed 650V/1100V, single core cable for panel board wiring as per IS:694:1990 with ISI Mark
ORA plain copper PVC insulated unsheathed650/1100V., Single Core Cable for panel board wiring as per IS:694:1990 |
Area in
Sq. mm |
Conductor
construction |
Cond. dia
mm |
Max. DC resistance
ohm/km at 20*C |
Insulation thinkness
in mm |
Cable dia
(App.) |
Current Rating
in Amp. |
0.50 |
16/0.20 |
0.94 |
39.00 |
0.60 |
2.20 |
4 |
0.75 |
24/0.20 |
1.20 |
26.00 |
0.60 |
2.50 |
7 |
1.00 |
32/0.20 |
1.34 |
19.50 |
0.60 |
2.60 |
11 |
1.50 |
48/0.20 |
1.64 |
13.30 |
0.60 |
2.90 |
14 |
2.50 |
80/0.20 |
2.08 |
7.98 |
0.70 |
3.50 |
19 |
4.00 |
56/0.20 |
2.61 |
4.95 |
0.80 |
4.30 |
26 |
35.00 |
220/0.45 |
8.70 |
0.554 |
1.40 |
11.60 |
91 |
50.00 |
325/0.45 |
10.60 |
0.386 |
1.60 |
13.90 |
120 |
Note: As per the international practice which is also adopted by BIS, the size of the conductor is decided by its resistance only. The construction of the conductor mentioned in the table list are only for guidelines and are as per market convention. It may vary within the prescribed limit of IS:8130-1994 with related classes and tables. |
PVC Insulated & Sheathed H.D Cables for Electric Supply & Control Purposes
PVC insulated & PVC sheathed 1.1KV copper control cables as per IS:1554 (Pt.1)
Conductor: Circular/ Solid/ Stranded Copper.
Insulation: PVC (Type A or Type C)
Sheath: PVC (ST1 or ST2).
Armoured: G.I wire /G.I strip./Al.wire/Al. strip
Jelly Filled Communication Cables
We manufacture all types of shielded/ non shielded multipair, coaxial & communication cables as well as cables used for CCTV, Fire Alarm, Access Control, BMS, Public Address Systems & for Security Applications alongwith LAN cables shielded/non shielded, armoured / unarmoured as per client's requirement.
Instrumentation & data signalling cables
We manufacture all types of Shielded viz. Al. foil(with drain wire) / Braided cables for 4-20mA remote signaling applications or data transmission.
Also cables with individually shielded twisted pair single or multicore cables as per client's requirement can be supplied.
Specialized Cables
We also manufacture cables with highly flexible PVC compound which can be used in continuous movement applications such as travelling cables.
Also the cables suitable for Outdoor applications & Low temperature conditions thoroughly tested as per IS:694:1990 norms can be provided on request.